Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Anal Chem ; 93(27): 9383-9389, 2021 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-34192456

RESUMO

This paper describes the design, fabrication, and feasibility of paper-based optode devices (PODs) for sensing potassium selectively in biological fluids. PODs operate in exhaustive mode and integrate with a handheld, smartphone-connected optical reader. This integrated measuring system provides significant advantages over traditional optode membranes and other paper-based designs, by obtaining a linear optical response to potassium concentration via a simple, stackable design and by harnessing a smartphone to provide an easy-to-use interface, thus enabling remote monitoring of diseases.


Assuntos
Potássio , Smartphone
2.
JMIR Mhealth Uhealth ; 9(1): e19465, 2021 01 20.
Artigo em Inglês | MEDLINE | ID: mdl-33470941

RESUMO

BACKGROUND: Due to the complexity and chronicity of heart failure, engaging yet simple patient self-management tools are needed. OBJECTIVE: This study aimed to assess the feasibility and patient engagement with a smartphone app designed for heart failure. METHODS: Patients with heart failure were randomized to intervention (smartphone with the Habits Heart App installed and Bluetooth-linked scale) or control (paper education material) groups. All intervention group patients were interviewed and monitored closely for app feasibility while receiving standard of care heart failure management by cardiologists. The Atlanta Heart Failure Knowledge Test, a quality of life survey (Kansas City Cardiomyopathy Questionnaire), and weight were assessed at baseline and final visits. RESULTS: Patients (N=28 patients; intervention: n=15; control: n=13) with heart failure (with reduced ejection fraction: 15/28, 54%; male: 20/28, 71%, female: 8/28, 29%; median age 63 years) were enrolled, and 82% of patients (N=23; intervention: 12/15, 80%; control: 11/13, 85%) completed both baseline and final visits (median follow up 60 days). In the intervention group, 2 out of the 12 patients who completed the study did not use the app after study onboarding due to illnesses and hospitalizations. Of the remaining 10 patients who used the app, 5 patients logged ≥1 interaction with the app per day on average, and 2 patients logged an interaction with the app every other day on average. The intervention group averaged 403 screen views (per patient) in 56 distinct sessions, 5-minute session durations, and 22 weight entries per patient. There was a direct correlation between duration of app use and improvement in heart failure knowledge (Atlanta Heart Failure Knowledge Test score; ρ=0.59, P=.04) and quality of life (Kansas City Cardiomyopathy Questionnaire score; ρ=0.63, P=.03). The correlation between app use and weight change was ρ=-0.40 (P=.19). Only 1 out of 11 patients in the control group retained education material by the follow-up visit. CONCLUSIONS: The Habits Heart App with a Bluetooth-linked scale is a feasible way to engage patients in heart failure management, and barriers to app engagement were identified. A larger multicenter study may be warranted to evaluate the effectiveness of the app. TRIAL REGISTRATION: ClinicalTrials.gov NCT03238729; http://clinicaltrials.gov/ct2/show/NCT03238729.


Assuntos
Insuficiência Cardíaca/terapia , Aplicativos Móveis , Participação do Paciente , Qualidade de Vida/psicologia , Estudos de Viabilidade , Feminino , Hábitos , Insuficiência Cardíaca/psicologia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Volume Sistólico
3.
Angew Chem Int Ed Engl ; 59(41): 17810-17855, 2020 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-31165560

RESUMO

All matter has density. The recorded uses of density to characterize matter date back to as early as ca. 250 BC, when Archimedes was believed to have solved "The Puzzle of The King's Crown" using density.[1] Today, measurements of density are used to separate and characterize a range of materials (including cells and organisms), and their chemical and/or physical changes in time and space. This Review describes a density-based technique-magnetic levitation (which we call "MagLev" for simplicity)-developed and used to solve problems in the fields of chemistry, materials science, and biochemistry. MagLev has two principal characteristics-simplicity, and applicability to a wide range of materials-that make it useful for a number of applications (for example, characterization of materials, quality control of manufactured plastic parts, self-assembly of objects in 3D, separation of different types of biological cells, and bioanalyses). Its simplicity and breadth of applications also enable its use in low-resource settings (for example-in economically developing regions-in evaluating water/food quality, and in diagnosing disease).


Assuntos
Bioquímica , Magnetismo , Ciência dos Materiais
4.
ACS Sens ; 4(5): 1120-1125, 2019 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-31008585

RESUMO

In this Perspective, we examine the role of cost in sensor design, its meaning within the context of converting academic prototypes into commercial products, and the importance of these issues to clear scientific communication. The possible motivations to consider the cost of a technology, sensor, or assay are both numerous and apparent. However, the idea that the cost of reagents and materials at the laboratory scale will directly translate to the purchase price for a user is inaccurate. While calculating the bill of materials is easy, there are many business considerations that make commercial products entirely different from academic prototypes. With these critical aspects of commercialization considered, academics are often not equipped to predict what the final price of an assay, sensor, or instrument will be to the end user. When used without proper context and accuracy, an overreliance on the phrase "low cost" in the absence of a sufficient discussion of cost weakens the meaning of this popular term and precludes practical scientific advancements. To demonstrate how the relationship between a bill of materials and "expected purchase price" breaks down when considering academic innovations, we discuss pregnancy tests as a case study where an academic bill of materials can lead to both overestimations and underestimations of pricing.


Assuntos
Comércio , Desenho de Equipamento/economia , Feminino , Guias como Assunto , Humanos , Gravidez , Testes de Gravidez/economia
5.
Lab Chip ; 16(20): 3929-3939, 2016 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-27713998

RESUMO

Iron deficiency anemia (IDA) is a nutritional disorder that impacts over one billion people worldwide; it may cause permanent cognitive impairment in children, fatigue in adults, and suboptimal outcomes in pregnancy. IDA can be diagnosed by detection of red blood cells (RBCs) that are characteristically small (microcytic) and deficient in hemoglobin (hypochromic), typically by examining the results of a complete blood count performed by a hematology analyzer. These instruments are expensive, not portable, and require trained personnel; they are, therefore, unavailable in many low-resource settings. This paper describes a low-cost and rapid method to diagnose IDA using aqueous multiphase systems (AMPS)-thermodynamically stable mixtures of biocompatible polymers and salt that spontaneously form discrete layers having sharp steps in density. AMPS are preloaded into a microhematocrit tube and used with a drop of blood from a fingerstick. After only two minutes in a low-cost centrifuge, the tests (n = 152) were read by eye with a sensitivity of 84% (72-93%) and a specificity of 78% (68-86%), corresponding to an area under the curve (AUC) of 0.89. The AMPS test outperforms diagnosis by hemoglobin alone (AUC = 0.73) and is comparable to methods used in clinics like reticulocyte hemoglobin concentration (AUC = 0.91). Standard machine learning tools were used to analyze images of the resulting tests captured by a standard desktop scanner to 1) slightly improve diagnosis of IDA-sensitivity of 90% (83-96%) and a specificity of 77% (64-87%), and 2) predict several important red blood cell parameters, such as mean corpuscular hemoglobin concentration. These results suggest that the use of AMPS combined with machine learning provides an approach to developing point-of-care hematology.


Assuntos
Anemia Ferropriva/sangue , Anemia Ferropriva/diagnóstico , Fracionamento Celular , Eritrócitos/patologia , Estudos de Casos e Controles , Tamanho Celular , Humanos , Aprendizado de Máquina
6.
Anal Chem ; 88(12): 6326-33, 2016 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-27243791

RESUMO

This paper describes the design and fabrication of a "pop-up" electrochemical paper-based analytical device (pop-up-EPAD) to measure beta-hydroxybutyrate (BHB)-a biomarker for diabetic ketoacidosis-using a commercial combination BHB/glucometer. Pop-up-EPADs are inspired by pop-up greeting cards and children's books. They are made from a single sheet of paper folded into a three-dimensional (3D) device that changes shape, and fluidic and electrical connectivity, by simply folding and unfolding the structure. The reconfigurable 3D structure makes it possible to change the fluidic path and to control timing; it also provides mechanical support for the folded and unfolded structures that enables good registration and repeatability on folding. A pop-up-EPAD designed to detect BHB shows performance comparable to commercially available plastic test strips over the clinically relevant range of BHB in blood when used with a commercial glucometer that integrates the ability to measure glucose and BHB (combination BHB/glucometer). With simple modifications of the electrode and the design of the fluidic path, the pop-up-EPAD also detects BHB in buffer using a simple glucometer-a device that is more available than the combination BHB/glucometer. Strategies that use a "3D pop-up"-that is, large-scale changes in 3D structure and fluidic paths-by folding/unfolding add functionality to EPADs (e.g., controlled timing, fluidic handling and path programming, control over complex sequences of steps, and alterations in electrical connectivity) and should enable the development of new classes of paper-based diagnostic devices.


Assuntos
Ácido 3-Hidroxibutírico/sangue , Técnicas Eletroquímicas/métodos , Papel , Ácido 3-Hidroxibutírico/química , Biomarcadores/sangue , Cetoacidose Diabética/diagnóstico , Técnicas Eletroquímicas/instrumentação , Eletrodos , Humanos , Limite de Detecção , NAD/química , Sistemas Automatizados de Assistência Junto ao Leito
7.
Anal Chem ; 87(18): 9170-8, 2015 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-26241835

RESUMO

This paper demonstrates that, for applications in resource-limited environments, expensive microplate spectrophotometers that are used in many central laboratories for parallel measurement of absorbance of samples can be replaced by photometers based on inexpensive and ubiquitous, consumer electronic devices (e.g., scanners and cell-phone cameras). Two devices, (i) a flatbed scanner operating in transmittance mode and (ii) a camera-based photometer (constructed from a cell phone camera, a planar light source, and a cardboard box), demonstrate the concept. These devices illuminate samples in microtiter plates from one side and use the RGB-based imaging sensors of the scanner/camera to measure the light transmitted to the other side. The broadband absorbance of samples (RGB-resolved absorbance) can be calculated using the RGB color values of only three pixels per microwell. Rigorous theoretical analysis establishes a well-defined relationship between the absorbance spectrum of a sample and its corresponding RGB-resolved absorbance. The linearity and precision of measurements performed with these low-cost photometers on different dyes, which absorb across the range of the visible spectrum, and chromogenic products of assays (e.g., enzymatic, ELISA) demonstrate that these low-cost photometers can be used reliably in a broad range of chemical and biochemical analyses. The ability to perform accurate measurements of absorbance on liquid samples, in parallel and at low cost, would enable testing, typically reserved for well-equipped clinics and laboratories, to be performed in circumstances where resources and expertise are limited.


Assuntos
Fotometria/economia , Fotometria/instrumentação , Cor , Equipamentos e Provisões Elétricas , Fenômenos Ópticos , Papel
8.
Anal Chem ; 87(14): 7485-91, 2015 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-26091185

RESUMO

This paper describes a method of isolating small, highly accurate density-standard beads and characterizing their densities using accurate and experimentally traceable techniques. Density standards have a variety of applications, including the characterization of density gradients, which are used to separate objects in a variety of fields. Glass density-standard beads can be very accurate (±0.0001 g cm(-3)) but are too large (3-7 mm in diameter) for many applications. When smaller density standards are needed, commercial polymer microspheres are often used. These microspheres have standard deviations in density ranging from 0.006 to 0.021 g cm(-3); these distributions in density make these microspheres impractical for applications demanding small steps in density. In this paper, commercial microspheres are fractionated using aqueous multiphase systems (AMPS), aqueous mixture of polymers and salts that spontaneously separate into phases having molecularly sharp steps in density, to isolate microspheres having much narrower distributions in density (standard deviations from 0.0003 to 0.0008 g cm(-3)) than the original microspheres. By reducing the heterogeneity in densities, this method reduces the uncertainty in the density of any specific bead and, therefore, improves the accuracy within the limits of the calibration standards used to characterize the distributions in density.


Assuntos
Fracionamento Químico , Microesferas , Polímeros/química , Polímeros/isolamento & purificação , Calibragem/normas , Tamanho da Partícula , Padrões de Referência , Água/química
9.
Anal Chem ; 87(12): 6158-64, 2015 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-25978093

RESUMO

Combining aqueous multiphase systems (AMPS) and magnetic levitation (MagLev) provides a method to produce hybrid gradients in apparent density. AMPS­solutions of different polymers, salts, or surfactants that spontaneously separate into immiscible but predominantly aqueous phases­offer thermodynamically stable steps in density that can be tuned by the concentration of solutes. MagLev­the levitation of diamagnetic objects in a paramagnetic fluid within a magnetic field gradient­can be arranged to provide a near-linear gradient in effective density where the height of a levitating object above the surface of the magnet corresponds to its density; the strength of the gradient in effective density can be tuned by the choice of paramagnetic salt and its concentrations and by the strength and gradient in the magnetic field. Including paramagnetic salts (e.g., MnSO4 or MnCl2) in AMPS, and placing them in a magnetic field gradient, enables their use as media for MagLev. The potential to create large steps in density with AMPS allows separations of objects across a range of densities. The gradients produced by MagLev provide resolution over a continuous range of densities. By combining these approaches, mixtures of objects with large differences in density can be separated and analyzed simultaneously. Using MagLev to add an effective gradient in density also enables tuning the range of densities captured at an interface of an AMPS by simply changing the position of the container in the magnetic field. Further, by creating AMPS in which phases have different concentrations of paramagnetic ions, the phases can provide different resolutions in density. These results suggest that combining steps in density with gradients in density can enable new classes of separations based on density.


Assuntos
Campos Magnéticos , Cloretos/química , Compostos de Manganês/química , Polietilenoglicóis/química , Sais/química , Soluções , Sulfatos/química , Tensoativos/química , Termodinâmica , Água/química
11.
Angew Chem Int Ed Engl ; 54(20): 5836-53, 2015 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-25914299

RESUMO

Despite the growth of research in universities on point-of-care (POC) diagnostics for global health, most devices never leave the laboratory. The processes that move diagnostic technology from the laboratory to the field--the processes intended to evaluate operation and performance under realistic conditions--are more complicated than they might seem. Two case studies illustrate this process: the development of a paper-based device to measure liver function, and the development of a device to identify sickle cell disease based on aqueous multiphase systems (AMPS) and differences in the densities of normal and sickled cells. Details of developing these devices provide strategies for forming partnerships, prototyping devices, designing studies, and evaluating POC diagnostics. Technical and procedural lessons drawn from these experiences may be useful to those designing diagnostic tests for developing countries, and more generally, technologies for use in resource-limited environments.


Assuntos
Anemia Falciforme/diagnóstico , Anemia Falciforme/economia , Testes de Função Hepática/economia , Sistemas Automatizados de Assistência Junto ao Leito/economia , Humanos
12.
Am J Hematol ; 90(1): 31-6, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25263455

RESUMO

This paper demonstrates the enrichment of reticulocytes by centrifuging whole blood through aqueous multiphase systems (AMPSs)-immiscible phases of solutions of polymers that form step-gradients in density. The interfaces of an AMPS concentrate cells; this concentration facilitates the extraction of blood enriched for reticulocytes. AMPS enrich reticulocytes from blood from both healthy and hemochromatosis donors. Varying the osmolality and density of the phases of AMPS provides different levels of enrichment and yield of reticulocytes. A maximum enrichment of reticulocytemia of 64 ± 3% was obtained from donors with hemochromatosis. When used on peripheral blood from normal donors, AMPS can provide a higher yield of enriched reticulocytes and a higher proportion of reticulocytes expressing CD71 than differential centrifugation followed by centrifugation over Percoll. Blood enriched for reticulocytes by AMPS could be useful for research on malaria. Several species of malaria parasites show a preference to invade young erythrocytes and reticulocytes; this preference complicates in vitro cultivation of these species in human blood. Plasmodium knowlesi malaria parasites invade normal human blood enriched for reticulocytes by AMPSs at a rate 2.2 times greater (P < 0.01) than they invade unenriched blood. Parasite invasion in normal blood enriched by AMPS was 1.8 times greater (P < 0.05) than in blood enriched to a similar reticulocytemia by differential centrifugation followed by centrifugation over Percoll. The enrichment of reticulocytes that are invaded by malaria parasites demonstrates that AMPSs can provide a label-free method to enrich cells for biological research.


Assuntos
Centrifugação com Gradiente de Concentração/métodos , Dextranos/química , Ficoll/química , Polietilenoglicóis/química , Álcool de Polivinil/química , Reticulócitos/citologia , Sangue , Soluções Tampão , Centrifugação com Gradiente de Concentração/instrumentação , Hemocromatose/sangue , Humanos , Concentração Osmolar , Plasmodium falciparum/crescimento & desenvolvimento , Plasmodium knowlesi/crescimento & desenvolvimento , Contagem de Reticulócitos , Reticulócitos/parasitologia
13.
PLoS One ; 9(12): e114540, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25490722

RESUMO

Although simple and low-cost interventions for sickle cell disease (SCD) exist in many developing countries, child mortality associated with SCD remains high, in part, because of the lack of access to diagnostic tests for SCD. A density-based test using aqueous multiphase systems (SCD-AMPS) is a candidate for a low-cost, point-of-care diagnostic for SCD. In this paper, the field evaluation of SCD-AMPS in a large (n = 505) case-control study in Zambia is described. Of the two variations of the SCD-AMPS used, the best system (SCD-AMPS-2) demonstrated a sensitivity of 86% (82-90%) and a specificity of 60% (53-67%). Subsequent analysis identified potential sources of false positives that include clotting, variation between batches of SCD-AMPS, and shipping conditions. Importantly, SCD-AMPS-2 was 84% (62-94%) sensitive in detecting SCD in children between 6 months and 1 year old. In addition to an evaluation of performance, an assessment of end-user operability was done with health workers in rural clinics in Zambia. These health workers rated the SCD-AMPS tests to be as simple to use as lateral flow tests for malaria and HIV.


Assuntos
Anemia Falciforme/diagnóstico , Testes Diagnósticos de Rotina/métodos , Eritrócitos/patologia , Adolescente , Contagem de Células , Criança , Pré-Escolar , Coleta de Dados , Testes Diagnósticos de Rotina/economia , Feminino , Pessoal de Saúde , Humanos , Lactente , Masculino , Serviços de Saúde Rural , Manejo de Espécimes , Fatores de Tempo , Volatilização , Zâmbia
14.
Proc Natl Acad Sci U S A ; 111(41): 14864-9, 2014 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-25197072

RESUMO

Although effective low-cost interventions exist, child mortality attributable to sickle cell disease (SCD) remains high in low-resource areas due, in large part, to the lack of accessible diagnostic methods. The presence of dense (ρ > 1.120 g/cm(3)) cells is characteristic of SCD. The fluid, self-assembling step-gradients in density created by aqueous multiphase systems (AMPSs) identifies SCD by detecting dense cells. AMPSs separate different forms of red blood cells by density in a microhematocrit centrifuge and provide a visual means to distinguish individuals with SCD from those with normal hemoglobin or with nondisease, sickle-cell trait in under 12 min. Visual evaluation of a simple two-phase system identified the two main subclasses of SCD [homozygous (Hb SS) and heterozygous (Hb SC)] with a sensitivity of 90% (73-98%) and a specificity of 97% (86-100%). A three-phase system identified these two types of SCD with a sensitivity of 91% (78-98%) and a specificity of 88% (74-98%). This system could also distinguish between Hb SS and Hb SC. To the authors' knowledge, this test demonstrates the first separation of cells by density with AMPSs, and the usefulness of AMPSs in point-of-care diagnostic hematology.


Assuntos
Anemia Falciforme/diagnóstico , Separação Celular/métodos , Anemia Falciforme/genética , Contagem de Células , Separação Celular/economia , Centrifugação , Variação Genética , Humanos , Sistemas Automatizados de Assistência Junto ao Leito/economia , Curva ROC , Fatores de Tempo
15.
Proc Natl Acad Sci U S A ; 111(33): 11984-9, 2014 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-25092346

RESUMO

This paper describes an inexpensive, handheld device that couples the most common forms of electrochemical analysis directly to "the cloud" using any mobile phone, for use in resource-limited settings. The device is designed to operate with a wide range of electrode formats, performs on-board mixing of samples by vibration, and transmits data over voice using audio--an approach that guarantees broad compatibility with any available mobile phone (from low-end phones to smartphones) or cellular network (second, third, and fourth generation). The electrochemical methods that we demonstrate enable quantitative, broadly applicable, and inexpensive sensing with flexibility based on a wide variety of important electroanalytical techniques (chronoamperometry, cyclic voltammetry, differential pulse voltammetry, square wave voltammetry, and potentiometry), each with different uses. Four applications demonstrate the analytical performance of the device: these involve the detection of (i) glucose in the blood for personal health, (ii) trace heavy metals (lead, cadmium, and zinc) in water for in-field environmental monitoring, (iii) sodium in urine for clinical analysis, and (iv) a malarial antigen (Plasmodium falciparum histidine-rich protein 2) for clinical research. The combination of these electrochemical capabilities in an affordable, handheld format that is compatible with any mobile phone or network worldwide guarantees that sophisticated diagnostic testing can be performed by users with a broad spectrum of needs, resources, and levels of technical expertise.


Assuntos
Técnicas Eletroquímicas/instrumentação , Antígenos de Protozoários/análise , Glicemia/análise , Eletrodos , Monitoramento Ambiental/instrumentação , Humanos , Metais Pesados/análise , Proteínas de Protozoários/análise , Sódio/urina
16.
Ann Indian Acad Neurol ; 17(1): 58-61, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24753661

RESUMO

CONTEXT: To evaluate the additional information that susceptibility weighted sequences and datasets would provide in acute stroke. AIMS: The aim of this study were to assess the value addition of susceptibility weighted magnetic resonance imaging (SWI) of brain in patients with acute arterial infarct. MATERIALS AND METHODS: All patients referred for a complete brain magnetic resonance imaging (MRI) between March 2010 and March 2011 at our institution had SWI as part of routine MRI (T1, T2, and diffusion imaging). Retrospective study of 62 consecutive patients with acute arterial infarct was evaluated for the presence of macroscopic hemorrhage, petechial micro-bleeds, dark middle cerebral artery (MCA) sign and prominent vessels in the vicinity of infarct. RESULTS: SWI was found to detect hemorrhage not seen on other routine MRI sequences in 22 patients. Out of 62 patients, 17 (10 petechial) had hemorrhage less than 50% and 5 patients had greater than 50% area of hemorrhage. A "dark artery sign" due to thrombus within the artery was seen in 8 out of 62 patients. Prominent cortical and intraparenchymal veins were seen in 14 out of 62 patients. CONCLUSIONS: SWI has been previously shown to be sensitive in detecting hemorrhage; however is not routinely used in stroke evaluation. Our study shows that SWI, by virtue of identifying unsuspected hemorrhage, central occluded vessel, and venous congestion is additive in value to the routine MR exam and should be part of a routine MR brain in patients suspected of having an acute infarct.

18.
Nano Lett ; 12(8): 4060-4, 2012 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-22668343

RESUMO

This paper demonstrates the use of aqueous multiphase systems (MuPSs) as media for rate-zonal centrifugation to separate nanoparticles of different shapes and sizes. The properties of MuPSs do not change with time or during centrifugation; this stability facilitates sample collection after separation. A three-phase system demonstrates the separation of the reaction products (nanorods, nanospheres, and large particles) of a synthesis of gold nanorods, and enriches the nanorods from 48 to 99% in less than ten minutes using a benchtop centrifuge.

19.
J Am Chem Soc ; 134(22): 9094-7, 2012 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-22594904

RESUMO

This Communication demonstrates the generation of over 300 phase-separated systems-ranging from two to six phases-from mixtures of aqueous solutions of polymers and surfactants. These aqueous multiphase systems (MuPSs) form self-assembling, thermodynamically stable step-gradients in density using a common solvent, water. The steps in density between phases of a MuPS can be very small (Δρ ≈ 0.001 g/cm(3)), do not change over time, and can be tuned by the addition of co-solutes. We use two sets of similar objects, glass beads and pellets of different formulations of Nylon, to demonstrate the ability of MuPSs to separate mixtures of objects by differences in density. The stable interfaces between phases facilitate the convenient collection of species after separation. These results suggest that the stable, sharp step-gradients in density provided by MuPSs can enable new classes of fractionations and separations based on density.


Assuntos
Polímeros/isolamento & purificação , Tensoativos/isolamento & purificação , Centrifugação com Gradiente de Concentração , Polímeros/química , Propriedades de Superfície , Tensoativos/química , Termodinâmica , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...